TFIX-8ST / Universal facade fixing with screw and integrated insulation cap

SKU:
EAN:
Prekės ženklas: Rawlplug
Disko diametras: 60 mm
Grežiamos skylės diametras: 8 mm
Minimalus gręžiamos skylės gylis ( medžiaga A, B, C, D): 40 mm
Efektyvus įtvirtinimo gylis ( medžiaga A, B, C, D): 25 mm
Minimalus gręžiamos skylės gylis ( medžiaga E): 80 mm
Efektyvus įtvirtinimo gylis ( medžiaga E): 65 mm
Priedai: Tool for installation TFIX-8ST
Statybinių medžiagų klasės: A, B, C, D, E
Taško temperatūros laidumas [W/K}: 0.001 ( izoliacijos storis 115 - 155 mm)
Taško temperatūros laidumas [W/K}: 0.002 (izoliacijos storis 175 - 335 mm)

Versatile screw-in facade fixing with integral insulation cap. Used for fastening of polystyrene (EPS) boards, mineral wool, and polyurethane (PU) boards.

Advantages-application:

  • accurate countersunk setting - automatically sets the fixing flush with the insulation layer
  • integrated insulation cap (with unique surface reinforcement) equalizes thermal conductivity over the fixing point, whilst also leveling out drying times of render
  • unique sleeve compression zone for precision installations
  • simple countersunk installation in all substrates (A, B, C, D, E)
  • the long plastic over moulding on the TFIX-8ST screw minimizes thermal bridging (value 0.001-0,002W/K), contributing to energy-saving benefits
  • the shortest embedment depth at the maximum strength parameters
  • unique design allows for high load-bearing capacities. This reduces the quantity of fixings required per square meter of insulation
  • plate stiffness (value 0.6 kN/mm) ensures smooth elevation surface and stable insulation system
  • pre-assembled elements of the fixing saves time and labor

Approved for:

  • concrete C12/15-C50/60 (Use category A)
  • solid brick (Use category B)
  • solid sand-lime brick (Use category B)
  • hollow brick (Use category C)
  • hollow sand-lime brick (Use category C)
  • hollow lightweight concrete block (Use category C)
  • vertically-perforated clay block (Use category C)
  • lightweight concrete block (Use category C)
  • reinforced components of lightweight aggregate concrete (Use category D)
  • aerated concrete block (Use category E)

Application:

  • External Thermal Insulation Composite Systems (ETICS);
  • Polystyrene (EPS) boards;
  • Mineral wool;
  • Polyurethane (PU) boards.

Installation tips:

  • drill a hole of required diameter and depth
  • lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached
  • when using the TFIX-8ST-TOOL setting tool (can be found in the accessories section) the teeth should be embedded in the insulation material after hammering
  • embedment depth of min 25mm in A, B, C, D materials and 65mm in Aerated Concrete Block
  • drilling depth of min 40mm in A, B, C, D materials and 80mm in Aerated Concrete Block