TFIX-8ST / Universal facade fixing with screw and integrated insulation cap
SKU: | |
EAN: | |
Brand: | Rawlplug |
Disk diameter: | 60 mm |
Diameter: | 8 mm |
Min. drill hole depth (Subst. A,B,C,D): | 40 mm |
Effect. anchoring depth (Subst. A,B,C,D): | 25 mm |
Min. drill hole depth (Subst. E): | 80 mm |
Effect. anchoring depth (Subst. E): | 65 mm |
Accessories: | Tool for installation TFIX-8ST |
Building material classes: | A, B, C, D, E |
Point thermal transmittance [W/K]: | 0.001 (for insulation thickness 115-155 mm) |
Point thermal transmittance [W/K]: | 0.002 (for insulation thickness 175-335 mm) |
Versatile screw-in facade fixing with integral insulation cap. Used for fastening of polystyrene (EPS) boards, mineral wool, and polyurethane (PU) boards.
Advantages-application:
- accurate countersunk setting - automatically sets the fixing flush with the insulation layer
- integrated insulation cap (with unique surface reinforcement) equalizes thermal conductivity over the fixing point, whilst also leveling out drying times of render
- unique sleeve compression zone for precision installations
- simple countersunk installation in all substrates (A, B, C, D, E)
- the long plastic over moulding on the TFIX-8ST screw minimizes thermal bridging (value 0.001-0,002W/K), contributing to energy-saving benefits
- the shortest embedment depth at the maximum strength parameters
- unique design allows for high load-bearing capacities. This reduces the quantity of fixings required per square meter of insulation
- plate stiffness (value 0.6 kN/mm) ensures smooth elevation surface and stable insulation system
- pre-assembled elements of the fixing saves time and labor
Approved for:
- concrete C12/15-C50/60 (Use category A)
- solid brick (Use category B)
- solid sand-lime brick (Use category B)
- hollow brick (Use category C)
- hollow sand-lime brick (Use category C)
- hollow lightweight concrete block (Use category C)
- vertically-perforated clay block (Use category C)
- lightweight concrete block (Use category C)
- reinforced components of lightweight aggregate concrete (Use category D)
- aerated concrete block (Use category E)
Application:
- External Thermal Insulation Composite Systems (ETICS);
- Polystyrene (EPS) boards;
- Mineral wool;
- Polyurethane (PU) boards.
Installation tips:
- drill a hole of required diameter and depth
- lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached
- when using the TFIX-8ST-TOOL setting tool (can be found in the accessories section) the teeth should be embedded in the insulation material after hammering
- embedment depth of min 25mm in A, B, C, D materials and 65mm in Aerated Concrete Block
- drilling depth of min 40mm in A, B, C, D materials and 80mm in Aerated Concrete Block